전체메뉴

  • PDF Catalog Download

Michigan Technology

Application reference

Delivery and construction

Applications

Ulsan Hweya Wastewater Treatment Plant(DOF)

Site Location 43-14, Mulgeonneo-gil, Ungchon-myeon, Ulju-gun, Ulsan
Buyer Ulsan City, Hyundai Construction
Contract date December, 2006
(Delivery)Commissioning date September, 2008
Capacity 32,000㎥/day
Technology Dissolved Ozone Flotation(DOF System)
Raw Water Municipal Wastewater from city sewage
Construction cost(USD) 2,142,200
Power(USD/㎥) 0.019
Total Operating cost(USD/㎥) 5.0 cents
Water Quality Analysis Results
BOD COD TSS TN TP
Influent 8.5 17.0 8.5 12.0 1.9
Effluent 4.3 10.2 4.0 10.2 0.4

Jinju Munsan Wastewater Treatment Plant(DAF)

Site Location 154, Worasan-ro 1117 beon-gil, Munsan-eup, Jinju-si, Gyeongsangnam-do
Buyer Jinju City, Environmental Management
Contract date May, 2010
(Delivery)Commissioning date March, 2011
Capacity 7,100㎥/day
Technology Dissolved Air Flotation(DAF system)
Raw Water Municipal Wastewater from City sewage
Construction cost(USD) 713,000
Power(USD/㎥) 0.004
Total Operating cost(USD/㎥) 5.0 cents
Water Quality Analysis Results
BOD COD TSS TN TP
Influent 6.0 25.0 10.0 14.0 1.8
Effluent 4.0 20.0 4.0 12.0 0.2

Jinju Sabong Wastewater Trearment Plant(DAF)

Site Location 44-25, Dongbu-ro 1960beon-gil, Sabong-myeon, Jinju-si, Gyeongsangnam-do
Buyer Jinju City, Environmental Management
Contract date May, 2010
(Delivery)Commissioning date March, 2011
Capacity 2,500㎥/day
Technology Dissolved Air Flotation(DAF system)
Raw Water Municipal Wastewater from City sewage
Construction cost(USD) 448,800
Power(USD/㎥) 0.007
Total Operating cost(USD/㎥) 5.0 cents
Water Quality Analysis Results
BOD COD TSS TN TP
Influent 7.0 25.0 10.0 16.0 1.8
Effluent 4.0 20.0 4.5 12.5 0.2

Pyeongtaek Cheongbook Wastewater treatment Plant(DOF)

Site Location 365, Cheongbugnam-ro, Cheongbug-myeon, Pyeongtaek-si, Gyeonggi-do
Buyer Hanwha Construction
Contract date April, 2009
(Delivery)Commissioning date April, 2011
Capacity 2,700㎥/day
Technology Dissolved Ozone Flotation(DOF system)
Raw Water Municipal Wastewater from City sewage
Construction cost(USD) 990,000
Power(USD/㎥) 0.025
Total Operating cost(USD/㎥) 5.6 cents
Water Quality Analysis Results
BOD COD TSS TN TP
Influent 5.0 20.0 2.0 15.0 2.0
Effluent 2.5 9.0 1.5 12.0 0.1

Wollong Industrial Wastewater Trearment Plant(DOF)

Site Location 434, Hyuam-ro Wollong-myeon, Paju-si, Gyeonggi-do
Buyer Environmental Management, Hanwha Construction
Contract date February, 2009
(Delivery)Commissioning date June, 2011
Capacity 17,000㎥/day
Technology Dissolved Ozone Flotation(DOF system)
Raw Water Industrial Wastewater from LG Display + City sewage
Construction cost(USD) 4,190,000
Power(USD/㎥) 0.038
Total Operating cost(USD/㎥) 5.0 cents
Water Quality Analysis Results
BOD COD TSS TN TP
Influent 10.0 40.0 15.0 20.0 0.6
Effluent 6.0 16.0 5.0 19.5 0.18

Yeongcheon Industrial Wastewater Trearment Plant(DAF)

Site Location 22, Sangnigongdan-gil, Gogyeong-myeon, Yeongcheon-si, GyeongsangBuk-do
Buyer Yeongcheon City
Contract date August, 2013
(Delivery)Commissioning date December, 2013
Capacity 150㎥/day
Technology Dissolved Air Flotation(DAF system)
Raw Water Industrial Wastewater from agriculture industrial complex
Construction cost(USD) 225,798
Power(USD/㎥) 0.062
Total Operating cost(USD/㎥) 5.0 cents
Water Quality Analysis Results
BOD COD TSS TN TP
Influent 30.0 40.0 30.0 60.0 0.7
Effluent 28.5 38.0 15.0 28.0 0.3

Jinju Jeongchon Industrial Wastewater Treatment Plant(DAF)

Site Location 33-5, Hwagaecheon-ro 54beon-gil, Jeongchon-myeon, Jinju-si, Gyeongsangnam-do
Buyer Jinju City, Environmental Management
Contract date December, 2010
(Delivery)Commissioning date November, 2011
Capacity 2,250㎥/day
Technology Dissolved Air Flotation(DAF system)
Raw Water Industrial Wastewater from industrial Complex
Construction cost(USD) 430,332
Power(USD/㎥) 0.008
Total Operating cost(USD/㎥) 5.0 cents
Water Quality Analysis Results
BOD COD TSS TN TP
Influent 10.0 26.0 10.0 16.0 1.6
Effluent 8.0 20.0 4.0 15.5 0.3

Busan sinhang Wastewater treatment Plant(DOF)

Site Location 231, Sinhang 8-ro, Jinghae-gu, Changwon-si, Gyeonsangnam-do
Buyer Busan Port Authority, Daerim Industrial
Contract date September, 2012
(Delivery)Commissioning date March, 2014
Capacity 8,000㎥/day
Technology Dissolved Ozone Flotation(DOF system)
Raw Water Municipal Wastewater from City sewage
Construction cost(USD) 2,080,000
Power(USD/㎥) 0.015
Total Operating cost (USD/㎥) 6.24 cents
Water Quality Analysis Results
BOD COD TSS TN TP
Influent 5.0 15.0 5.0 18.0 3.2
Effluent 5.0 10.0 5.0 18.0 0.3

Anyang Wastewater Treatment Plant(DAF)

Site Location 19, Hwachang-ro, Manan-gu, Anyang-si, Gyeonggi-do
Buyer Anyang City, Korea Development
Contract date July, 2014
(Delivery)Commissioning date March, 2015
Capacity 13,000㎥/day
Technology Dissolved Air Flotation(DAF system)
Raw water Municipal Wastewater from City sewage
Construction cost(USD) 402,000
Power(USD/㎥) 0.011
Total Operating cost(USD/㎥) 5.0 cents
Water Quality Analysis Results
BOD COD TSS TN TP
Influent 149.2 149.2 552.2 23.7 54.3
Effluent 29.8 7.6 52.2 4.7 5.4

Yeosu Industrial Wastewater Treatment Plant(DAF)

Site Location 1201, Yeosusanfan-ro, Yeosu-si, Jeollanam-do
Buyer Kolon Water & Energy, Hyosung Corporation
Contract date January, 2015
(Delivery)Commissioning date April, 2015
Capacity 70,000㎥/day
Technology Dissolved Air Flotation(DAF system)
Raw Water Industrial Wastewater from industrial complex
Construction cost(USD) 1,287,000
Power(USD/㎥) 0.006
Total Operating cost(USD/㎥) 5.0 cents
Water Quality Analysis Results
BOD COD TSS TN TP
Influent - - 50.0 - 3.0
Effluent - - 10.0 - 0.75

Gwangju Industrial Wastewater Treatment Plant(DAF)

Site Location 114, Gobong-ro, Gwangsan-gu, Gwangju
Buyer Korea Railroad Corporation, Daerim Industrial
Contract date July, 2013
(Delivery)Commissioning date June, 2015
Capacity 180㎥/day
Technology Dissolved Air Flotation(DAF system)
Raw Water Industrial Wastewater from industrial complex
Construction cost(USD) 460,000
Power(USD/㎥) 0.016
Total Operating cost(USD/㎥) 5.0 cents
Water Quality Analysis Results
BOD COD TSS TN TP
Influent 200.0 150.0 200.0 45.0 5.5
Effluent 110.0 100.0 100.0 40.0 1.5

Pocheon Jangja Wastewater treatment Plant(DAF)

Site Location 95-4, Jangjagyeongje-ro, Sinbuk-myeon, Pocheon-si, Gyeonggi-do
Buyer Sinpyeong Industrial Complex Development
Contract date June, 2014
(Delivery)Commissioning date October, 2016
Capacity 19,350㎥/day
Technology Dissolved Air Flotation(DAF system)
Raw Water Industrial Wastewater from industrial complex
Construction cost(USD) 635,000
Power(USD/㎥) 0.003
Total Operating cost(USD/㎥) 13.9 cents
Water Quality Analysis Results
BOD COD TSS TN TP
Influent 10.1 58.5 13.8 17.4 1.9
Effluent 7.2 44.5 7.5 15.8 0.4

Eumseong CJ Foodville Wastewater Pretreatment Plant(DAF)

Site Location 20, Daesosandan-ro, Daeso-myeon, Eumseong-gun, Chungcheongbuk-do
Buyer CJ Logistics
Contract date December, 2018
(Delivery)Commissioning date October, 2019
Capacity 500㎥/day
Technology Dissolved Air Flotation(DAF system)
Raw Water Food factory Wastewater from CJ Foodville co.,Ltd
Construction cost(USD) 289,000
Power(USD/㎥) 0.034
Total Operating cost(USD/㎥) 36.2 cents
Water Quality Analysis Results
BOD COD TSS TN TP
Influent 1879.3 1691.4 963.4 47.0 9.40
Effluent 879.2 791.2 250.4 44.0 2.93

Eumseong Pulmuone sengmyun Wastewater Pretreatment Plant(DAF)

Site Location 730-27, Samyang-ro, Daeso-myeon, Eumseong-gun, Chungcheongbuk-do
Buyer CJ Logistics
Contract date June, 2018
(Delivery)Commissioning date March, 2019
Capacity 1,250㎥/day
Technology Dissolved Air Flotation(DAF system)
Raw Water Food factory Wastewater from Pulmuone co.,Ltc
Construction cost(USD) 230,000
Power(USD/㎥) 0.014
Total Operating cost(USD/㎥) 19.7 cents
Water Quality Analysis Results
BOD COD TSS TN TP
Influent 1471.4 980.9 499.1 58.9 3.82
Effluent 904.2 602.8 153.4 54.3 1.17

Kyung San Industrial Wastewater Treatment Plant(DAF)

Site Location 46, Gyungan-ro 87-gil, Gyeongsan-si, Gyeongsangbuk-do
Buyer Environmental Facilities Management
Contract date July, 2018
(Delivery)Commissioning date November, 2019
Capacity 100,000㎥/day
Technology Dissolved Air Flotation(DAF system)
Raw Water Municipal Wastewater from City sewage
Construction cost(USD) 650,000
Power(USD/㎥) 0.006
Total Operating cost(USD/㎥) 5.0 cents
Water Quality Analysis Results
BOD COD TSS TN TP
Influent 10.0 19.0 15.0 18.0 1.4
Effluent 7.0 15.0 10.0 18.0 0.3

Phosphorus removal system at Kijang WWTP(DAF)

Site Location 564, Gijang-daero, Gijang-eup, Gijang-gun, Busan
Buyer Busan Metropolitan City
Contract date May, 2019
(Delivery)Commissioning date July, 2020
Capacity 13,500㎥/day
Technology Dissolved Air Flotation(DAF system)
Raw Water Municipal Wastewater from City sewage
Construction cost(USD) 365
Power(USD/㎥) 0.006
Total Operating cost(USD/㎥) 2.5 cents
Water Quality Analysis Results
BOD COD TSS TN TP
Influent 10.0 40.0 10.0 20.0 2.0
Effluent 4.5 18.0 3.0 15.0 0.18

Water recycling facility at Yangsan WWTP (DOF)

Site Location 54, Gangbyeon-ro, Dong-myeon, Yangsan-si, Gyeongsangnam-do
Buyer Yangsan City
Contract date April, 2020
(Delivery)Commissioning date April, 2021
Capacity 22,000㎥/day
Technology Dissolved Ozone Flotation(DOF system)
Raw Water Municipal Wastewater from City sewage
Construction cost(USD) 880
Power(USD/㎥) 0.008
Total Operating cost(USD/㎥) 1.658
Water Quality Analysis Results
BOD COD TSS TN TP
Influent 4.0 60 19,000 16.7 0.25
Effluent 2.0 12 25 15.0 0.10

Hana Industry (DOF)

Site Location 34-15, Dongcheon-ro 7beon-gil, Geumjeong-gu, Busan
Buyer Hana Industry
Contract date August, 2022
(Delivery)Commissioning date August, 2022
Capacity 100㎥/day
Technology Dissolved Ozone Flotation(DOF System)
Raw Water Livestock wastewater
Construction cost(USD) 118,182
Power(USD/㎥) -
Total Operating cost(USD/㎥) -
Water Quality Analysis Results
BOD COD TSS TN TP
Influent 5329.2 - - - -
Effluent 2472.2 - - - -

Phosphorus removal system at Kyungsan WWTP (MIDAF)

Site Location 18, Gyeongan-ro 87-gil, Gyeongsan-si, Gyeongsangbuk-do
Buyer Environmental Facilities Management
Contract date November, 2020
(Delivery)Commissioning date May, 2023
Capacity 25,000㎥/day
Technology Dissolved Air Flotation (DAF System)
Raw Water Domestic wastewater
Construction cost(USD) 542,700
Power(USD/㎥) 0.0054
Total Operating cost(USD/㎥) 1.8 cents
Water Quality Analysis Results
BOD COD TSS TN TP
Influent 9 19 9 13 1.5
Effluent 5 12 6.5 12 0.2

Supply Performance



Water treatment target Description Status Facility capacity
Drinking water Filtration facility renovation at Bangeojin water work, Ulsan(MIDAF) shutdown 6,500㎥/day
Domestic wastewater Advanced treatment facility at Hweya WWTP, Ulsan(DOF) Operational 32,000㎥/day
Advanced Treatment Plant at Hwayng WWTP, Cheongdo (DOF) Operational 7,600㎥/day
Water recycling facility at Cheongbuk WWTP of Pyeongtaek (DOF) Operational 2,700㎥/day
Advanced treatment at Munsan Sewage Disposal Plant in Jinju (MIDAF) Operational 7,100㎥/day
Advanced treatment at Munsan Sewage Disposal Plant in Jinju (MIDAF) Operational 2,500㎥/day
Advanced WWTP at Ungdong in Busan New Port (DOF) Operational 8,000㎥/day
Sewage Treatment Plant at Seoksu in Anyang (MIDAF) Under construction 13,000㎥/day
Phosphorus removal system at Kijang WWTP (MIDAF) Operational 13,500㎥/day
Water recycling facility at Yangsan WWTP, Yangsan (DOF) Operational 22,000㎥/day
Phosphorus removal system at Kyungsan WWTP (MIDAF) Operational 25,000㎥/day
Industrial wastewater Tertiary 1st WWTP of industrial park, Wolnong, Paju (DOF) Operational 9,000㎥/day
Advanced WWTP of industrial park, Wolnong, Paju (MIDAF) Operational 9,000㎥/day
Advanced WWTP, Jeongchon (MIDAF) Operational 2,250㎥/day
Tertiary 2nd WWTP of industrial park, Wolnong, Paju (DOF) Operational 8,000㎥/day
Advanced WWTP of agriculture & industrial park, Gokyung, Youngcheon (MIDAF) Operational 150㎥/day
WWTP in parking station of Honam Rapid Train, Gwangju (MIDAF) Operational 180㎥/day
WWTP in industrial park, Sinpyung, Pocheon (MIDAF) Operational 19,350㎥/day
WWTP in industrial park, Wonlnae, Yeosu (MIDAF) Operational 70,000㎥/day
WWTP of PPEC, Eumseong, Chungbuk (MIDAF) Operational 1,250㎥/day
Nationail WWTP (east region), Kyungsan (MIDAF) Operational 100,000㎥/day
WWTP of CJ Foodville, Eumseong, Chungbuk (MIDAF) Operational 500㎥/day
Livestock wastewater Advanced Trearment at public livestock WWTP, Pocheon (DOF-PO2) Operational 170㎥/day
Advanced Treatment at public livestock WWTP, Boryeong (DOF-PO2) Operational 120㎥/day
Hana Industry (DOF) Operational 100㎥/day
Lake Dongtan(2) district water recycle system (MIDAF) Operational 16,000㎥/day